Прошу регистрируйтесь на сайте, это позволит вам писать комментарии, задавать вопросы на форуме.
мужчина
женщина
The signal is missing from the solenoid valve for the fuel quantity to the front bank, cylinders 1-3.
Fault on the solenoid valve or open circuit in the solenoid valve circuit.
The engine runs very unevenly if the fuel supply to all cylinders is not working correctly.
Check the circuit components, harness-to-harness connectors and electrical cables. Clear the fault code memory, start the engine and rev it up. Check that the engine is running smoothly and reacts normally to the accelerator. Renew the solenoid valve if the fault persists.
Short circuit to ground in high pressure solenoid valve.
Damaged cable harness or harness-to-component connectors.
The solenoid valve closes and the engine shuts down when there is no more gas in the circuit.
Check the electrical cables and harness-to-harness connectors for short circuit. Check the gas shut-off valve.
Для написания необходимо зарегистрироваться и подтвердить e-mail