The voltage has been above the permitted level for one of the sensors which has a shared voltage supply.
The fuel level sensor, which is currently the only sensor in this sensor group, is shorted to battery voltage.
The fault causes reductant injection to be switched off.
Check the circuit components, harness-to-harness connectors and electrical cables.
The sensor resistance should be between 397 ohms and 92 ohms.