Fault code: EMS 1683 SCANIA

";

Finding the fault code

Enter the fault code





Fault code EMS 1683

Cooling fan for auxiliary cooler

Error identification:

The voltage in the circuit has been outside the permitted range.


Cause:

Short circuit to ground in the auxiliary cooler fan circuit.


Notes:

If the cooling fan is electrically controlled (T123), it cannot be switched off.

If the cooling fan is hydraulically controlled (V119), it will not work at all.


Action:

Check the fan solenoid valve along with the circuit harness-to-harness connectors and electrical cables.